Installing feed rolls (R500 WF EUR/EUR+ / RA50 4R )
Always ensure that the feed rolls are suitable for the filler wire (diameter and material) in question. Select the wire feed rolls according to the tables here: Wire feeder consumables.
| 1. | Release the pressure handles on the wire feed mechanism. |
| 2. | Open the pressure roll locking arms. |
| 3. | Detach the pressure roll mounting pins and drive roll mounting caps. |
| 4. | Install the drive rolls. Align the cut on the drive rolls' bottom with the pin on the drive shaft. |
| 5. | Attach the drive roll mounting caps. |
| 6. | Install the pressure rolls and mounting pins (there are no alignment cuts on the bottom of the pressure rolls). |
| 7. | Continue to installing the filler wire (refer to Installing wire (R500 WF EUR/EUR+)) or close the locking arms and pressure handles on the feed rolls. |